MOTOR STARTER COMPONENTS

Thermal Overload Relays

Protect your motor against sustained overload. Find the right relay configuration for your starter, match the adjustment range to your motor and bring your contactor, reset and signaling requirements together.

Concept illustration of an industrial motor, pump, conveyor and closed control cabinet
01 / ADJUSTMENT

Motor current

Choose an adjustment band that includes your motor nameplate current.

02 / COORDINATION

Starter compatibility

Confirm the contactor and relay as a compatible combination.

03 / CONTROL

Reset & signaling

Specify the restart arrangement and auxiliary contact requirements.

BDDKG / 02

Overload protection that works with your starter

A thermal overload relay senses motor current. In a bimetallic design, heating causes the sensing elements to move; when the overload response reaches the relay’s trip characteristic, its control contacts change state. The starter control circuit then releases the contactor.

SWITCH

Contactor

Switches the motor power in response to the control circuit. Select it for the motor duty, operating voltage and required switching frequency.

MONITOR

Thermal overload relay

Responds to sustained overload and opens the appropriate control path. Current range, trip characteristic and reset behavior depend on the exact relay.

INTERRUPT

Fuse or circuit breaker

Provides the required short-circuit interruption. A thermal overload relay normally does not interrupt short-circuit current by itself.

BDDKG / 03

Explore thermal overload relay configurations

Start with the mounting arrangement and the motor duty. Ask Bddkg for the available series and exact datasheets to confirm your selection.

COMPACT STARTER

Direct contactor mounting

A compatible relay mounts directly to its intended contactor. Check the mechanical interface, terminal arrangement, current path and supported accessory combination before finalizing your starter layout.

FLEXIBLE LAYOUT

Separate mounting

A supported mounting base allows the overload relay to be installed separately in the panel. Confirm the base reference, terminal access, space and connection requirements for the selected series.

RESET OPTION

Manual reset

A deliberate reset action is required after a trip and the necessary cooling period. Review the cause of the trip and the complete restart circuit before returning equipment to service.

RESET OPTION

Automatic reset

The relay can reset after cooling where this mode is supported. Assess the complete control circuit and unintended-restart risk before specifying automatic reset.

BDDKG / 04

Choose the relay around your motor

Use the motor nameplate and starter details as your starting point. A motor power figure alone does not establish the correct overload setting.

CURRENT

01 / Motor nameplate

Record rated current at the intended voltage and motor connection. Include frequency and a nameplate photograph when requesting a selection.

RANGE

02 / Adjustment band

Select a relay band that contains the required motor current. Apply the exact manufacturer instructions and circuit requirements when setting the dial.

TRIP CHARACTERISTIC

03 / Starting duty

Describe acceleration time, starting method and starts per hour. Compare the relay’s time-current curve with the actual motor starting and running conditions.

COMPATIBILITY

04 / Starter combination

Provide the contactor reference and required mounting arrangement. Verify supported mechanical and electrical compatibility using the relevant combination data.

INTEGRATION

05 / Control functions

Specify reset mode, stop or test needs and trip signaling. Confirm contact arrangements and ratings for the control circuit rather than assuming every relay is identical.

OPERATING CONDITIONS

06 / Installation

Review enclosure temperature, mounting orientation, terminal data and environmental limits. Check any applicable derating and installation instructions.

BDDKG / 05

Which motor-protection device fits your circuit?

Compare the required functions before choosing a device. Thermal relays, electronic relays and motor circuit breakers have different operating arrangements.

Thermal overload relay

PRIMARY ROLE

Motor overload response through starter control contacts.

SELECTION CHECK

Needs a suitable contactor and coordinated short-circuit protection.

Electronic overload relay

PRIMARY ROLE

Electronic current sensing and model-specific protection functions.

SELECTION CHECK

Compare sensing range, supply needs, trip functions and diagnostics by model.

Motor protection circuit breaker

PRIMARY ROLE

Motor circuit switching and protective functions defined by its release.

SELECTION CHECK

Check whether overload protection is included and verify the starter combination.

BDDKG / 06

Compare the details that determine fit

Request these details for each proposed model. Keep the exact part reference beside its ratings so your purchasing team can compare like for like.

PROTECTION DATA

Electrical & trip data

Adjustment range; rated operating conditions; trip class and time-current curves; phase-loss or unbalance response where declared; auxiliary contact arrangement and ratings.

INSTALLATION DATA

Mounting & connections

Compatible contactor references; direct or separate mounting; base and accessory references; dimensions; conductor sizes; tightening instructions and terminal access.

CONTROL DATA

Reset & operating limits

Supported reset modes; test and stop functions; cooling and reset instructions; ambient temperature limits; compensation and derating information where applicable.

BDDKG / 07

Motor overload protection across everyday industry

Use your driven load to describe the application, then verify the motor, starter and environment together.

FLUID HANDLING

Pumps & water systems

State the pump duty, start frequency and normal motor current. Include operating conditions that may lead to prolonged overload or stalled operation.

HVAC

Fans & ventilation

Provide acceleration time and control method. If the motor uses a drive, follow the drive manufacturer’s protection and switching requirements.

AUTOMATION

Conveyors & machinery

Describe load inertia, starts per hour and normal duty. Starting under load and frequent cycling can influence the required trip characteristic.

PANEL ASSEMBLY

Control-panel builders

Send the starter schedule, contactor series, control voltage and panel layout requirements. Confirm protection coordination before assembling the final panel.

OEM EQUIPMENT

Machine manufacturers

Include motor data, operating sequence and reset philosophy in your brief. Check that the protection and restart arrangement supports the intended machine operation.

SERVICE SUPPORT

Replacement & maintenance

Identify the existing relay and contactor references. Confirm ratings, terminal arrangement and mounting compatibility rather than selecting from appearance alone.

BDDKG / 08

Specify a coordinated motor starter

A successful combination connects overload response, controlled switching and short-circuit protection. Matching body sizes does not establish a tested combination.

DEVICE REFERENCES

Check the complete combination

Use the exact relay, contactor and upstream protective-device references. Review combination tables for the intended operating voltage and prospective fault current.

DOCUMENTED PERFORMANCE

Define your project requirements

State the required coordination type and applicable destination requirements. Ask for supporting documents covering the proposed references and operating conditions.

ASSEMBLY CHECK

Confirm the installation details

Review the control wiring, terminal assignments and accessory instructions for the selected devices. Use the manufacturer’s drawings for the actual installation.

BDDKG / 09

Continue your motor-control review

Use these resources to clarify switching and overload roles before sending your specification.

BDDKG GUIDE

Contactor vs circuit breaker

Understand the switching and protective roles within a motor circuit.

MANUFACTURER REFERENCE

Manual or automatic reset?

See a manufacturer explanation of reset modes. The details apply to the named products and must be verified for your selected relay.

BDDKG / 10

Thermal overload relay selection questions

Practical answers before you confirm a model.

It responds to sustained motor overload according to its time-current characteristic. Its control contacts operate the starter circuit so that a contactor can disconnect the motor.

Normally no. Select suitable short-circuit protection and verify the relay, contactor and protective device as a coordinated starter combination.

Choose a band that includes the motor nameplate current at its intended voltage and connection. Establish the setting using the exact relay instructions and the circuit design requirements.

Trip class describes an overload relay’s operating-time characteristic under specified conditions. Match the declared characteristic to motor starting time and protection needs; do not assume all thermal relays have the same class.

Yes. Verify mounting, terminal arrangement, current rating and supported accessories. A visually similar relay is not evidence of compatibility with your contactor.

No universal assumption should be made. Check the selected model’s declared phase-failure or phase-unbalance behavior, test conditions and limitations.

Only where the manufacturer supports that application and provides the required connections. Phase-sensitive relays can require a specific arrangement; follow the exact product instructions.

Manual reset needs a deliberate action after a trip and cooling. Automatic reset can restore the relay contacts after cooling. Whether the motor can restart depends on the complete starter control circuit.

Investigate the motor start profile, load, settings, supply and installation conditions. Compare the device curve with the duty before changing the selection; do not raise the overload setting merely to mask a fault.

Send motor rated current, voltage, starting method, starting time, contactor reference, mounting and reset needs, quantity, installation conditions and destination-market documentation requirements.

BDDKG / 11

Find the right overload relay for your starter

Send Bddkg your motor and contactor details. Request the available relay references, matching datasheets and supporting documentation for your project.

Tell us about your motor circuit

Start with the details that matter

Include a motor nameplate photograph and the contactor reference. Add your quantity, required reset mode, installation conditions and delivery destination.