BDDKG / SOLAR & DC PROTECTION
Specify protection around your DC system. Compare breaker formats and confirm voltage, fault interruption, pole configuration and current direction for solar PV, battery storage and DC distribution.
Discuss your DC requirementsFor distributors · Panel builders · PV integrators · Project buyers

Confirm the maximum circuit voltage and the manufacturer-rated DC operating voltage for the complete pole arrangement.
Match the prospective short-circuit current to the stated DC breaking capacity at your operating voltage.
Check polarity, grounding and permitted pole connections together. The number of poles alone does not establish suitability.
A DC circuit breaker opens a circuit when an overcurrent condition reaches its trip characteristic. It helps protect conductors and equipment against sustained overloads and short circuits within the limits stated for the selected device. Your protection design must consider both normal service and the most demanding fault conditions.
Direct current does not provide the periodic natural current zero crossings of AC. Interrupting a DC fault therefore requires an appropriate arc-control design and a validated voltage and pole arrangement. An AC rating cannot be treated as a DC rating. Start with the exact device datasheet rather than a familiar housing or handle color.
Use these categories to describe your requirement. They are selection routes, not a statement that every rating or configuration is available. Ask for the proposed model and its current technical documents before including it in a specification.
A modular format for suitable branch circuits and compact assemblies. Compare its current range, trip curve, DC voltage, pole arrangement and terminal requirements.
A format to evaluate for feeder protection and applications requiring different frame sizes or release options. DC performance remains specific to the chosen model.
Select around string configuration, maximum PV voltage and potential reverse current. Confirm the protective device is suitable for the intended photovoltaic duty.
Evaluate maximum open-circuit voltage under the design temperature conditions, parallel-string contributions and coordination with the rest of the combiner assembly.
Account for the battery fault-current contribution and charging and discharging directions. A PV application rating alone does not establish battery suitability.
Confirm the DC bus voltage, grounding method, continuity requirements and selective coordination with upstream and downstream protective devices.

Your battery can feed a fault even when an inverter is switched off. Define the available fault current, maximum operating voltage and expected current direction before selecting a breaker. Coordinate the device with the battery manufacturer, system designer and other protective equipment.
Record the highest voltage the circuit may reach in service. For photovoltaic arrays, use the design maximum rather than only the nominal operating point. For a battery system, include its permitted charging conditions. Then verify the breaker DC voltage rating in the exact manufacturer-approved connection arrangement.
Do not multiply a single-pole voltage by the number of poles yourself. Series-pole arrangements are valid only where the manufacturer specifies them for the relevant circuit and grounding configuration.
Choose a rated current and trip characteristic that suit the load and protect the conductor under the applicable installation rules. Check continuous service, temporary current peaks and starting or charging behavior. Oversizing a breaker to prevent nuisance trips can leave the cable inadequately protected.
Ambient temperature, adjacent devices and enclosure conditions can affect usable current. Request derating information for your actual installation. A nominal rating on its own does not describe the completed panel's thermal performance.
Determine the prospective short-circuit current where the breaker will be installed. The stated breaking capacity must apply at your DC voltage, pole configuration and specified test conditions. A higher current rating does not automatically mean higher fault interruption capability.
Where a datasheet declares Icu and Ics, read both definitions and their stated conditions. They describe different test duties. Ask your designer whether backup protection or a documented device combination is needed, and use manufacturer coordination information for that combination.
Follow the exact positive, negative, line and load markings and connection diagram. Reversing a connection can affect interruption performance.
For battery charging and discharging, obtain explicit manufacturer confirmation that the device supports the required current directions and fault conditions.
Identify whether the DC system is grounded or unearthed. Coordinate protected conductors and pole usage with the system design and applicable rules.
Request model code, rated current in A, rated operating voltage in V DC, poles and permitted circuit arrangement.
Request DC breaking capacity in kA, trip characteristic, applicable operating conditions and coordination data.
Request dimensions, mounting, conductor capacity, terminal torque, temperature limits and compatible accessories.
Values are intentionally model-specific. Compare complete documented configurations rather than selecting the largest number from unrelated catalogue pages. Any missing field should be resolved before order approval.
IEC 60947-2 covers a class of low-voltage circuit breakers for operation by instructed or skilled persons. Its scope is not proof that a particular product is certified. The applicable standard, edition and market route must be checked against the exact device and its intended use.
Request the technical datasheet, installation instructions and relevant declaration, certificate or test report. Confirm that the model code and selected ratings are included in the document scope. A company-level certificate or an unrelated product report cannot establish the proposed breaker's electrical performance.
Request model documentationCheck enclosure temperature, pollution conditions, accessibility, cable bending space and terminal compatibility. Follow the manufacturer's instructions for conductor preparation and torque. Accessories and busbars should be selected from approved combinations, rather than assumed compatible because they appear to fit.
Installation, inspection and fault investigation belong to qualified personnel. Isolate all possible sources, including PV arrays and batteries, using the required safety procedure. This category overview does not replace the model-specific connection diagram or the electrical design.
Provides overcurrent protection within its verified DC ratings and trip characteristics. Confirm suitability for isolation if that function is required.
Provides a switching or isolation function within its declared duty. Do not assume a switch-disconnector provides automatic overload protection.
Limits transient overvoltages within its application scope. It complements overcurrent protection and does not replace the circuit breaker.
Send your application, maximum DC voltage, continuous current, prospective fault current, grounding arrangement and required current directions. Include the installation environment, mounting space, destination market and project standard. A single-line diagram helps the team understand where protection is required.
For purchasing, add your target quantity, expected repeat-order volume, delivery destination and any marking or packaging requirements. Ask for the exact proposed model, supporting documents and sample approval terms. Confirm availability, minimum order, lead time and warranty in the written offer rather than assuming category-wide terms.
Match the sample marking and model identifier to the quotation, datasheet and documentation. Resolve differences before placing the production order.
Review mechanical fit, terminals, accessories, labeling and thermal conditions in the intended panel. Appearance alone cannot verify DC performance.
Specify inspection records and relevant verification requirements with your supplier and qualified engineering team. Document the approved configuration for repeat orders.
Only when the manufacturer explicitly provides a suitable DC rating and approved connection arrangement for that exact device. An AC voltage marking alone is insufficient.
No. Verify the maximum PV voltage, current, fault duty and any PV-specific requirements against the proposed device documentation.
Do not assume so. Battery fault-current levels and current direction can differ from a PV circuit. Obtain explicit suitability confirmation for the intended battery application.
It can. Polarized devices rely on a specified connection direction. Follow the device markings and installation diagram, including every required series connection.
It indicates a specified ability to operate with current in either direction under declared conditions. Ask for model-level confirmation and the permitted circuit arrangement.
Pole selection depends on voltage, grounding, conductors to be interrupted and the manufacturer's tested arrangement. Pole count is not an independent voltage multiplier.
Coordinate the load, cable capacity, trip curve, installation rules and derating. A qualified designer should confirm the selected combination.
It describes interruption capability under stated test conditions. Check the DC voltage and configuration associated with the declared value.
No. They describe different breaking duties under the relevant standard. Compare their definitions and values for the exact proposed breaker.
Only if the breaker is declared suitable for the required isolation function and installation. Verify this separately from overcurrent performance.
A standard overcurrent circuit breaker is not a substitute for a coordinated DC surge protective device. Review transient protection separately.
Use combinations approved for the device and duty. Mechanical fit does not establish terminal compatibility, current capacity or adequate clearances.
Ask for documents applicable to the exact model, ratings and destination market. Check the issuing body, scope and current status.
Share your marking and packaging requirements with BDDKG. Confirm feasibility, sample approval and commercial terms for the selected product before ordering.
Provide application, DC voltage, current, fault level, poles, current direction, market, quantity and delivery destination. Attach your design requirements where available.
Tell us where the breaker will operate and which electrical conditions it must handle. BDDKG can review your product enquiry around the proposed model, installation needs and supporting documentation. Start with your circuit requirements so your quotation can address the details that matter.
Send your DC breaker enquiry Contact via WhatsApp Read IEC 60947-2 scope