CONTROL & SIGNALING / CATEGORY GUIDE

Push Buttons
& Pilot Lights

Give your operators a clear way to command equipment and recognise its status. Compare push buttons, illuminated operators, selector switches and pilot lights for your next control panel. Start with the required function, then match the mounting dimensions, contact arrangement and light-source supply to your design.

Request selection support
Concept illustration of push buttons and illuminated pilot lights on a brushed metal panel

Product appearance is illustrative.

02 BUYER FIT

Built around your panel requirements

Whether you build machinery, assemble electrical panels or source replacement operators, begin with a repeatable specification. Keep the mechanical interface, electrical function and visible signal consistent across your equipment.

Panel builders

Choose compatible heads, mounting collars, contact blocks and light modules as an assembly. Your bill of materials should identify every required part, so the workshop receives a complete operator.

Machine OEMs

Define the operator action and status meaning before selecting colours. A consistent interface helps your engineering team document the machine and keeps replacement decisions easier to review.

Maintenance teams

Record the existing part reference and photograph the rear assembly. Matching the visible bezel alone can leave you with incompatible contacts, mounting hardware or an incorrectly rated lamp.

03 PRODUCT TYPES

Find the right control device

These are functional categories for selection, rather than a promise of stock or a list of verified models. Confirm available references and model-specific data before placing your order.

Non-illuminated push buttons

For an operator command without a built-in status light. Specify momentary or maintained action and the required normally open or normally closed contacts.

Illuminated push buttons

Combine an operator command and local illumination. Treat the switching contacts and the light-source supply as separate specification items during electrical selection.

Pilot lights

Show an equipment condition through a dedicated indicator. Select the supply voltage, AC or DC suitability, lens colour and the required viewing conditions.

Selector switches

Give your operators a defined mode selection. Confirm the number of positions, maintained or spring-return action, and the contact sequence at every position.

Key-operated selectors

Restrict operation through a keyed control interface where your application requires it. Specify which positions allow key removal and document how keys are managed.

Emergency-stop operators

Select these only within a designed and validated emergency-stop function. A mushroom-shaped ordinary button does not establish suitability for a safety-related circuit.

Discuss available configurations

04 OPERATING PRINCIPLE

Command and indication do different jobs

A push button changes a control-circuit state when you operate it. A pilot light provides visual feedback from the circuit that drives its light source. An illuminated push button combines both functions physically, but the lamp does not automatically prove that the controlled machine has reached a safe or expected state.

05 CONTACT CHOICE

Specify the contact arrangement

Normally open and normally closed describe contact states with the operator in its normal condition. Your circuit determines which arrangement is required. Review the schematic and the device contact diagram together; never infer terminal assignments from a photograph.

Normally open / NO

The contact is open in its normal state and closes on the specified actuation. Check the exact operator action and diagram before selecting a block.

Normally closed / NC

The contact is closed in its normal state and opens on the specified actuation. Safety functions require additional device and system validation beyond an NC label.

Multiple contact blocks

Where a series supports multiple blocks, check its allowed assembly, contact timing and mounting limits. Extra contacts are not automatically interchangeable across product families.

06 OPERATOR ACTION

Momentary or maintained?

A momentary operator returns after release; a maintained operator remains in a selected state until operated again or reset according to its mechanism. Choose the action from your control logic, including restart behaviour after a loss of power. Do not use an operator's mechanical retention as a substitute for a properly designed control function.

07 ILLUMINATION

Match the light source to your supply

Specify the actual supply at the lamp terminals, including whether it is AC, DC or a supported combination. Similar-looking light modules can have different supply ratings. Confirm polarity requirements where applicable, operating tolerance and replacement method in the selected model documentation.

08 MECHANICAL SELECTION

Fit the complete assembly, front to back

Check the specified panel cut-out, anti-rotation detail, permitted panel thickness and mounting method against the manufacturer's drawing. Leave clearance for the rear contact blocks, wiring and door movement. A nominal mounting diameter alone does not establish interchangeability between different ranges.

Panel interface

Use the dimensional drawing for the ordered reference. Include hole spacing, bezel clearance and the access needed to tighten the mounting hardware.

Rear depth

Measure from the panel rear face to the furthest fitted accessory. Allow room for conductor routing and maintain access to the terminals.

Assembly compatibility

Confirm head, collar, lamp block and contact-block references together. Request a complete assembly list where a modular design is supplied as separate parts.

09 ELECTRICAL SELECTION

Check the actual switching duty

Select contacts for the control load and operating conditions in your circuit. A headline current value alone does not describe suitability for every voltage or load type. Review the rated operational values and applicable utilisation category for the selected model, along with the permitted conductor sizes and terminal requirements.

10 ENVIRONMENT

Choose protection for your installation

Consider dust, moisture, cleaning chemicals, vibration, temperature and exposure to sunlight where relevant. Verify whether an enclosure protection rating applies to the installed front face, the rear components or a complete enclosure. Correct panel preparation, seals and assembly instructions are part of achieving the declared protection.

11 APPLICATIONS

Operator interfaces across industrial equipment

Your application determines which functions need a physical control and which conditions need a visible indicator.

Concept illustration of an operator control station beside an automated conveyor

Conveyors, pumps and machine panels

For conveyor equipment, map local start, stop and mode controls to the complete machine control design. For pump panels, distinguish a command signal from confirmed pump operation. For machine stations, keep controls reachable and their meaning consistent with the operator documentation.

12 SELECTION WORKFLOW

Four decisions before you request a model

A short, complete specification is more useful than a photograph of the front of a switch.

01 / Define the function

List the command or condition, the required operator action and the number of contact circuits. Add the position sequence for a selector.

02 / Confirm the interface

Provide the cut-out drawing, panel thickness, available rear depth and required environmental protection. Include the existing reference for replacement enquiries.

03 / State electrical requirements

Provide control voltage, AC or DC, load type and contact duty. For illuminated devices, specify the light-source supply separately.

04 / Review the evidence: compare the proposed reference, dimensional drawing, contact diagram and relevant documents with your specification. Approve a sample where fit or operator feel matters before releasing a production order.

13 COMPARISON

Compare functions before comparing references

Use this comparison to narrow the device category. Numeric ratings and available configurations remain model-specific.

Push button

Primary job: command input. Key checks: momentary or maintained action, contact arrangement, contact duty and complete mounting assembly.

Pilot light

Primary job: visual indication. Key checks: light-source supply, AC/DC suitability, colour, visibility and interpretation of the monitored signal.

Illuminated operator

Primary job: command plus local indication. Key checks: both the contact specification and the light-source supply, with a clear definition of what illumination means.

14 DOCUMENTATION

Ask for evidence that matches the reference

Request the datasheet and dimensional drawing for the exact ordered assembly. Where your project specifies standards or approvals, check the stated scope, model identification and applicable market. IEC 60947-5-1 covers electromechanical control-circuit devices; mentioning a standard does not establish third-party certification for a product.

View the IEC standard scope

15 INSTALLATION REVIEW

Plan for installation and replacement

Have qualified personnel review the control design and follow the manufacturer's installation instructions. Before work, isolate the equipment and apply the site's safe working procedure. Check the fitted assembly, terminal identification, conductor preparation and specified tightening requirements. Verify operation within the complete equipment before returning it to service.

16 PURCHASING CHECKLIST

Make your enquiry easier to evaluate

Send your application, function, preferred operator style, contact arrangement, control voltage and illumination voltage. Include the mounting drawing, environmental conditions, destination market and expected quantities. For a replacement, attach the existing reference and clear photographs of both the front and rear.

If you need legends, packaging or another project-specific variation, describe the requirement and ask whether it is available for the proposed reference. Confirm minimum order quantity, sample terms, delivery schedule and commercial conditions in the quotation; these cannot be inferred from a generic category page.

Send your requirements

17 FAQ

Push buttons & pilot lights: your questions

Review common selection and sourcing questions before finalising your specification.

What is the difference between a push button and a pilot light?

A push button provides an operator input through its switching function. A pilot light indicates the state of the circuit connected to its light source. Choose them independently unless you need both functions in an illuminated operator.

Does an illuminated button confirm that equipment is running?

Only if the control design drives the lamp from an appropriate running-status signal. A lamp connected to a command signal may show that a command was issued without confirming actual equipment operation.

Can I replace a device with another of the same diameter?

Check the full drawing and assembly references first. Panel thickness, anti-rotation details, rear depth, mounting collars and contact-block interfaces may differ even when the nominal mounting diameter is the same.

How do I choose NO and NC contacts?

Use your circuit diagram and the model's contact diagram. Specify the required normal states and switching behaviour. A contact label alone does not validate the function of a complete machine control or safety circuit.

Are all LED pilot lights suitable for AC and DC?

No. Check the exact light-source reference and declared supply characteristics. The selected module must match your actual circuit voltage and AC or DC supply, including any relevant polarity requirements.

Should I choose momentary or maintained action?

Choose the action required by the control logic and intended operator task. Review what happens when the operator is released and after power is restored, rather than choosing only by appearance or preference.

Are metal and plastic operators interchangeable?

Do not assume that they are. Compare the mounting method, dimensions, environmental suitability and compatible blocks. Material alone does not establish electrical performance, installation compatibility or approval scope.

Can a normal mushroom button serve as an emergency stop?

Appearance alone is insufficient. Use an operator specifically suitable for the designed emergency-stop function and validate the complete safety-related system against the applicable project requirements.

Does a front-face protection rating cover the rear terminals?

Not necessarily. Read the declared scope and installation conditions. The exposed rear assembly may require an appropriate enclosure even when the installed operator front face has a declared protection rating.

Can I mix heads and blocks from different manufacturers?

Use only combinations supported by the relevant manufacturer documentation. Similar geometry or the ability to clip parts together does not confirm mechanical retention, electrical operation or declared performance.

Which information is needed for a selector switch?

Specify the number of positions, maintained or spring-return operation, required contact sequence and any key-removal positions. Include a function diagram when the operating sequence is important to your application.

Do you need a separate voltage for the illumination?

State the voltage actually supplied to the light source, even if it matches your control circuit voltage. Separating these requirements helps prevent the wrong lamp module being included in a modular assembly.

Which documents should accompany a purchase review?

Request the exact assembly references, datasheet, dimensional drawing, contact diagram and relevant installation instructions. Where project approvals are required, request documents that identify the model and applicable scope.

Can I request custom legends or packaging?

Describe the language, symbols, quantities and packaging requirements in your enquiry. Availability and commercial terms should be confirmed for the proposed reference before you approve artwork or place an order.

What should I send for a replacement enquiry?

Send the complete existing reference, clear front and rear photographs, supply details, contact requirements and panel dimensions. Note the machine function and any constraints on changing the existing assembly.

18 ENQUIRY

Specify a clearer operator interface

Bring your control function, electrical requirements and mounting constraints together in one enquiry. Your next step is to match those requirements to an exact reference and its documentation, then confirm the complete assembly and commercial terms before ordering.

Request technical documents Request a quotation

Request a Quote

Ready to Work Together? Build a project with us!